Nodal rhythm disorder

Last edited: 4/23/2026

Overview

Nodal rhythm disorder refers to abnormal cardiac rhythms originating from nodal tissue, often impacting the sinoatrial (SA) or atrioventricular (AV) nodes, leading to irregularities in heart rate and rhythm. These conditions can significantly affect cardiac function and patient outcomes 12345.

Diagnosis

  • Electrocardiogram (ECG) is essential for identifying nodal rhythm abnormalities, showing characteristic patterns such as SA block or AV dissociation 12345.
  • Holter monitoring may be necessary for prolonged evaluation of rhythm disturbances in patients with intermittent symptoms 12.
  • Electrophysiology studies can confirm the origin of the rhythm disorder and guide specific management strategies 134.
  • Management

  • Pacemaker implantation: For symptomatic bradycardia or AV block, leadless pacemakers (e.g., Micra) or traditional transvenous pacemakers may be indicated 1231617.
  • Pacing modes: Utilize dual-chamber pacing modes to maintain AV synchrony and potentially extend battery life 34.
  • Device optimization: Regular follow-up and reprogramming of pacemaker settings to optimize performance and battery longevity 22232.
  • Special Populations

  • Elderly: Increased risk of complications post-implantation; careful patient selection and monitoring are crucial 1251.
  • Comorbidities: Presence of conditions like tricuspid regurgitation may influence device choice and placement 1729.
  • Key Recommendations

  • Implant pacemaker for symptomatic nodal rhythm disorders: Consider leadless pacemakers for appropriate candidates to reduce complications and improve outcomes (Evidence: Moderate 1216).
  • Utilize dual-chamber pacing modes: To enhance AV synchrony and potentially extend device longevity (Evidence: Moderate 34).
  • Regular follow-up and device reprogramming: Essential for optimizing pacemaker function and patient outcomes (Evidence: Moderate 2232).
  • References

    Showing 100 most recent of 336 indexed papers.

    1 Ishizue N, Fukaya H, Oikawa J, Shinkai W, Suyama T, Toraiwa M et al.. A Novel Risk Score for Predicting the Difficulty in Leadless Pacemaker Implantation. Journal of cardiovascular electrophysiology 2026. link 2 Nakamura Y, Aiyama Y, Miki K, Kunimoto E, Ishikawa T, Arai S et al.. Sudden Micra VR Battery Failure With Telemetry Loss and Fluoroscopic Battery Deformation. Pacing and clinical electrophysiology : PACE 2026. link 3 Ip JE, Badie N, Rashtian M, Nair DG, Banker R, Hadadi C et al.. Novel Pacing Mode Conserves Battery in Dual-Chamber Leadless Pacemakers. Journal of cardiovascular electrophysiology 2026. link 4 Garweg C, Van Weyenbergh T, Sheldon T, Anders CC, Dorrestijn A, Poels P et al.. Behavior of leadless atrioventricular synchronous pacing during exercise. Heart rhythm 2025. link 5 Ludwik B, Labus M, Roleder T, Moskal P, Kiełbasa G, Śpikowski J et al.. Novel approach to left bundle branch area pacing lead implantation using a 3-dimensional stylet. Heart rhythm 2025. link 6 Troisi F, Caccavo VP, Santobuono VE, Sgarra L, Carella MC, Basile P et al.. Left atrial strain is a good predictor of atrio-ventricular synchrony in leadless pacemaker pacing. Journal of cardiovascular electrophysiology 2024. link 7 Pharithi RB, Ayeni M, Makharia M, Keene D, Khiani R. Optimizing conduction system pacing lead placement utilizing the image overlay technique. Pacing and clinical electrophysiology : PACE 2024. link 8 Bindi F, Vezzosi T, Sala G, Freccero F, Marmorini P, Bonelli F et al.. Evaluation of a smartphone electrocardiograph in healthy foals and comparison to standard base-apex electrocardiography. Veterinary research communications 2024. link 9 Tribulova N. Editorial for the . International journal of molecular sciences 2023. link 10 Li S, Dong J, Luo J, Wang G, Xie D, Zhou L. Comparison of different quantitative evaluation protocols for peri-device leak detection using cardiac computed tomography angiography after left atrial appendage closure. The international journal of cardiovascular imaging 2023. link 11 Toner L, Chen JXC, Ramchand J, Srivastava P, O'Donnell D, Calafiore P et al.. Biventricular Function is Impaired in Right Ventricular Septal Pacing-A Prospective Study Using Myocardial Strain Imaging. Heart, lung & circulation 2023. link 12 Shen J, Jiang L, Jiang F, Wu H, Cai X, Zhuo S et al.. Premature beat of selective left bundle branch: a novel marker for reaching and capturing the left bundle branch. Journal of interventional cardiac electrophysiology : an international journal of arrhythmias and pacing 2023. link 13 Chen X, Qian Z, Zou F, Wang Y, Zhang X, Qiu Y et al.. Differentiating left bundle branch pacing and left ventricular septal pacing: An algorithm based on intracardiac electrophysiology. Journal of cardiovascular electrophysiology 2022. link 14 Berdaoui B, Pintea Bentea G, Samyn S, Morissens M, Castro Rodriguez J. Leadless pacemaker implantation: An unexpected complication. Pacing and clinical electrophysiology : PACE 2022. link 15 Kumar P, Skrabal J, Frasure SE, Pourmand A. Pacemaker lead related myocardial perforation. The American journal of emergency medicine 2022. link 16 Shivamurthy P, Miller MA, El-Eshmawi A, Boateng P, Pandis D, Pawale A et al.. Leadless pacemaker implantation under direct visualization during valve surgery. The Journal of thoracic and cardiovascular surgery 2022. link 17 Niazi GZK, Masood A, Ahmed N, Qadir I, Akhtar A, Saleemi MS et al.. Permanent pacemaker implantation associated tricuspid regurgitation. Asian cardiovascular & thoracic annals 2021. link 18 D'Souza A, Wang Y, Anderson C, Bucchi A, Baruscotti M, Olieslagers S et al.. A circadian clock in the sinus node mediates day-night rhythms in Hcn4 and heart rate. Heart rhythm 2021. link 19 Tan K, Deng X, Wang S, Liu C, Zhao R, Xiong F. Transthoracic echocardiography-guided left bundle branch pacing without fluoroscopic guidance: A case report. Journal of clinical ultrasound : JCU 2021. link 20 Roston TM, Krahn AD, Ong K, Sanatani S. The merits of the ICD for inherited heart rhythm disorders: A critical re-appraisal. Trends in cardiovascular medicine 2020. link 21 Wang Y, Zhang Y, Wang W, Liu X, Chi Y, Lei J et al.. Effects of circadian rhythm disorder on the hippocampus of SHR and WKY rats. Neurobiology of learning and memory 2020. link 22 Jastrzębski M, Moskal P, Bednarek A, Kiełbasa G, Kusiak A, Sondej T et al.. Programmed deep septal stimulation: A novel maneuver for the diagnosis of left bundle branch capture during permanent pacing. Journal of cardiovascular electrophysiology 2020. link 23 Copertaro A, Bracci M. Working against the biological clock: a review for the Occupational Physician. Industrial health 2019. link 24 Wan J, Chen M, Wang Z, Everett TH, Rubart-von der Lohe M, Shen C et al.. Small-conductance calcium-activated potassium current modulates the ventricular escape rhythm in normal rabbit hearts. Heart rhythm 2019. link 25 García-Guasch L, Sá Borges C, Sousa P, Manubens Grau J. Identification and management of a subacute right ventricular perforation by an active-fixation permanent pacemaker lead in a dog. Journal of veterinary cardiology : the official journal of the European Society of Veterinary Cardiology 2019. link 26 Cipolletta L, Volpato G, Biffi M, Capucci A. An indissoluble knot: An unexpected troubleshooting during Micra implantation. Pacing and clinical electrophysiology : PACE 2019. link 27 Curnis A, Cerini M, Inama L, Vassanelli F, Mariggiò D, Salghetti F et al.. Management of a leadless pacemaker recall via extraction in a patient with a history of multiple previous device implants. Journal of electrocardiology 2019. link 28 Taborsky M, Skala T, Kocher M, Fedorco M. Extraction of a dislocated leadless pacemaker in a patient with infective endocarditis and repeated endocardial and epicardial pacing system infections. Biomedical papers of the Medical Faculty of the University Palacky, Olomouc, Czechoslovakia 2019. link 29 Van De Heyning CM, Elbarasi E, Masiero S, Brambatti M, Ghazal S, Al-Maashani S et al.. Prospective Study of Tricuspid Regurgitation Associated With Permanent Leads After Cardiac Rhythm Device Implantation. The Canadian journal of cardiology 2019. link 30 Potter BM, Ames MK, Toffoli AM, Scansen BA. Upper rate behavior in six dogs with dual-chamber pacemakers. Journal of veterinary cardiology : the official journal of the European Society of Veterinary Cardiology 2019. link 31 Mattson AR, Mattson E, Mesich ML, Yang Z, Iaizzo PA. Electrical parameters for physiological His-Purkinje pacing vary by implant location in an ex vivo canine model. Heart rhythm 2019. link 32 Curila K, Smida J, Herman D, Osmancik P, Stros P, Zdarska J et al.. Pacemaker reprogramming rarely needed after device replacement. Herz 2019. link 33 Marai I, Diab S, Ben-Avi R, Kachel E. Intraoperative Implantation of Micra Leadless Pacemaker During Valve Surgery. The Annals of thoracic surgery 2018. link 34 Akacem LD, Wright KP, LeBourgeois MK. Sensitivity of the circadian system to evening bright light in preschool-age children. Physiological reports 2018. link 35 Lee JZ, Ling J, Diehl NN, Hodge DO, Padmanabhan D, Killu AM et al.. Mortality and Cerebrovascular Events After Heart Rhythm Disorder Management Procedures. Circulation 2018. link 36 Mar PL, Chen G, Gandhi G, Tang ZZ, Leiserowitz A, Tripuraneni A et al.. Cost-effectiveness analysis of magnetic resonance imaging-conditional pacemaker implantation: Insights from a multicenter study and implications in the current era. Heart rhythm 2018. link 37 Huq AJ, Pertile MD, Davis AM, Landon H, James PA, Kline CF et al.. A Novel Mechanism for Human Cardiac Ankyrin-B Syndrome due to Reciprocal Chromosomal Translocation. Heart, lung & circulation 2017. link 38 Lopez-Villegas A, Catalan-Matamoros D, Robles-Musso E, Peiro S. Effectiveness of pacemaker tele-monitoring on quality of life, functional capacity, event detection and workload: The PONIENTE trial. Geriatrics & gerontology international 2016. link 39 Sharma G, Salahuddin S, Sanders P, Gupta H, Gulati G, Jagia P et al.. Inadequacy of fluoroscopy and electrocardiogram in predicting septal position in RVOT pacing - Validation with cardiac computed tomography. Indian heart journal 2016. link 40 Tzeis S, Andrikopoulos G, Weigand S, Grebmer C, Semmler V, Brkic A et al.. Right Bundle Branch Block-Like Pattern During Uncomplicated Right Ventricular Pacing and the Effect of Pacing Site. The American journal of cardiology 2016. link 41 Reynolds D, Duray GZ, Omar R, Soejima K, Neuzil P, Zhang S et al.. A Leadless Intracardiac Transcatheter Pacing System. The New England journal of medicine 2016. link 42 Ohlow MA, Roos M, Lauer B, Von Korn H, Geller JC. Incidence, predictors, and outcome of inadvertent malposition of transvenous pacing or defibrillation lead in the left heart. Europace : European pacing, arrhythmias, and cardiac electrophysiology : journal of the working groups on cardiac pacing, arrhythmias, and cardiac cellular electrophysiology of the European Society of Cardiology 2016. link 43 Pokorney SD, Zhou K, Matchar DB, Love S, Zeitler EP, Lewis R et al.. Optimal management of Riata leads with no known electrical abnormalities or externalization: a decision analysis. Journal of cardiovascular electrophysiology 2015. link 44 Zabek A, Malecka B, Haberka K, Boczar K, Pfitzner R, Debski M et al.. The analysis of indications and early results of transvenous lead extraction in patients with a pacemaker, ICD and CRT - single-center experience. Acta cardiologica 2015. link 45 Te CC, Stavrakis S, Lozano P, Reynolds D. Apparent acute reversible right ventricular pacing-induced left ventricular dysfunction. Journal of cardiovascular electrophysiology 2013. link 46 Kawakami T, Tanaka N, Ohno H, Kobayakawa H, Sakurai T, Ishihara H et al.. The relationship between right ventricular lead position and paced QRS duration. Pacing and clinical electrophysiology : PACE 2013. link 47 Ohlow MA, Lauer B, Brunelli M, Geller JC. Incidence and predictors of pericardial effusion after permanent heart rhythm device implantation: prospective evaluation of 968 consecutive patients. Circulation journal : official journal of the Japanese Circulation Society 2013. link 48 Korantzopoulos P, Grekas G, Goudevenos JA. Right-sided implantation of a cardiac resynchronization therapy defibrillator in a case of persistent left superior vena cava. Hellenic journal of cardiology : HJC = Hellenike kardiologike epitheorese 2013. link 49 Foster RG. Biological clocks: who in this place set up a sundial?. Current biology : CB 2012. link 50 Worley SJ, Gohn DC. Prolapsed double-canted bipolar left ventricular lead for pacing the left atrium via the coronary sinus: experience in 11 patients. Europace : European pacing, arrhythmias, and cardiac electrophysiology : journal of the working groups on cardiac pacing, arrhythmias, and cardiac cellular electrophysiology of the European Society of Cardiology 2012. link 51 Armaganijan LV, Toff WD, Nielsen JC, Andersen HR, Connolly SJ, Ellenbogen KA et al.. Are elderly patients at increased risk of complications following pacemaker implantation? A meta-analysis of randomized trials. Pacing and clinical electrophysiology : PACE 2012. link 52 Mabo P, Victor F, Bazin P, Ahres S, Babuty D, Da Costa A et al.. A randomized trial of long-term remote monitoring of pacemaker recipients (the COMPAS trial). European heart journal 2012. link 53 Sadarmin PP, Uberoi R, Tomlinson DR, Betts TR. ICD lead implantation following sharp cannulation of a blocked superior vena cava. Pacing and clinical electrophysiology : PACE 2011. link 54 Trocinski DR, Pickens AT. External monitoring-induced pacemaker-driven tachycardia: a case report. The Journal of emergency medicine 2011. link 55 Burri H, Park CI, Zimmermann M, Gentil-Baron P, Stettler C, Sunthorn H et al.. Utility of the surface electrocardiogram for confirming right ventricular septal pacing: validation using electroanatomical mapping. Europace : European pacing, arrhythmias, and cardiac electrophysiology : journal of the working groups on cardiac pacing, arrhythmias, and cardiac cellular electrophysiology of the European Society of Cardiology 2011. link 56 Zanon F, Svetlich C, Occhetta E, Catanzariti D, Cantù F, Padeletti L et al.. Safety and performance of a system specifically designed for selective site pacing. Pacing and clinical electrophysiology : PACE 2011. link 57 Tse HF, Saha S, Garg A, Bohn D, Lee YL, Lau CP. Muscle noise effects on atrial evoked response sensing: implications on atrial auto-threshold and auto-capture determination. Pacing and clinical electrophysiology : PACE 2011. link 58 Subramanian A, Selvaraj RJ, Cameron D. A tale of four atrioventricular intervals. Europace : European pacing, arrhythmias, and cardiac electrophysiology : journal of the working groups on cardiac pacing, arrhythmias, and cardiac cellular electrophysiology of the European Society of Cardiology 2010. link 59 Hayasaka N, LaRue SI, Green CB. Differential contribution of rod and cone circadian clocks in driving retinal melatonin rhythms in Xenopus. PloS one 2010. link 60 Sankhla V, Vajifdar B, Shah M, Lokhandwala Y. Left-sided biventricular pacemaker implantation in the presence of persistent left superior vena cava. Indian heart journal 2010. link 61 Biffi M, Bertini M, Saporito D, Ziacchi M, Martignani C, Diemberger I et al.. Actual pacemaker longevity: the benefit of stimulation by automatic capture verification. Pacing and clinical electrophysiology : PACE 2010. link 62 Huang ZM, Prasad C, Britton FC, Ye LL, Hatton WJ, Duan D. Functional role of CLC-2 chloride inward rectifier channels in cardiac sinoatrial nodal pacemaker cells. Journal of molecular and cellular cardiology 2009. link 63 Weiss R, Dov A, Fahrbach SE, Bloch G. Body size-related variation in Pigment Dispersing Factor-immunoreactivity in the brain of the bumblebee Bombus terrestris (Hymenoptera, Apidae). Journal of insect physiology 2009. link 64 Etsadashvili K, Hintringer F, Stühlinger M, Dichtl W, Spuller K, Antretter H et al.. Long-term results of high vs. normal impedance ventricular leads on actual (Real-Life) pacemaker generator longevity. Europace : European pacing, arrhythmias, and cardiac electrophysiology : journal of the working groups on cardiac pacing, arrhythmias, and cardiac cellular electrophysiology of the European Society of Cardiology 2009. link 65 van Opstal JM, Crijns HJ. Paradoxical increase of stimulus to atrium interval despite His-bundle capture during para-Hisian pacing. Europace : European pacing, arrhythmias, and cardiac electrophysiology : journal of the working groups on cardiac pacing, arrhythmias, and cardiac cellular electrophysiology of the European Society of Cardiology 2009. link 66 Pachón Mateos JC, Pachón Mateos EI, Pachón Mateos JC. Right ventricular apical pacing: the unwanted model of cardiac stimulation?. Expert review of cardiovascular therapy 2009. link 67 Crossley GH, Chen J, Choucair W, Cohen TJ, Gohn DC, Johnson WB et al.. Clinical benefits of remote versus transtelephonic monitoring of implanted pacemakers. Journal of the American College of Cardiology 2009. link 68 Antonelli D, Freedberg NA, Turgeman Y. Pacing and defibrillation lead exchange without vein puncture. Pacing and clinical electrophysiology : PACE 2009. link 69 van Eck JW, van Hemel NM, de Voogt WG, Meeder JG, Spierenburg HA, Crommentuyn H et al.. Routine follow-up after pacemaker implantation: frequency, pacemaker programming and professionals in charge. Europace : European pacing, arrhythmias, and cardiac electrophysiology : journal of the working groups on cardiac pacing, arrhythmias, and cardiac cellular electrophysiology of the European Society of Cardiology 2008. link 70 Bai R, Kam R, Ching CK, Hsu LF, Teo WS. Implantation of lumenless pacing leads at the inter-atrial septum and right ventricular outflow tract with deflectable catheter-sheath. Journal of Huazhong University of Science and Technology. Medical sciences = Hua zhong ke ji da xue xue bao. Yi xue Ying De wen ban = Huazhong keji daxue xuebao. Yixue Yingdewen ban 2008. link 71 Erdogan O, Aktoz M. Right ventricular outflow tract pacing: relation of high to low synchronous ventricular activation with cardiac memory. International journal of cardiology 2008. link 72 Pecora D, Morandi F, Liccardo M, Pepi P, Orazi S, Caico SI et al.. Performance of a ventricular automatic-capture algorithm in a wide clinical setting. Pacing and clinical electrophysiology : PACE 2008. link 73 Carbone V, Carerj S, Oreto G. Intermittent atrial sensing in a VDD pacemaker. Journal of electrocardiology 2008. link 74 Fard PJ, Moradi MH, Tajvidi MR. A novel approach in R peak detection using Hybrid Complex Wavelet (HCW). International journal of cardiology 2008. link 75 Gupta A, Halleran SM, Krishnan K, Trohman RG. Rescue permanent iliac vein pacing after epicardial lead failure: an unusual reversal of pacing fortune. Europace : European pacing, arrhythmias, and cardiac electrophysiology : journal of the working groups on cardiac pacing, arrhythmias, and cardiac cellular electrophysiology of the European Society of Cardiology 2008. link 76 MacKenzie R. Low amplitude P, QRS and T wave pattern in lead I--the "isoelectric lead I sign". Journal of insurance medicine (New York, N.Y.) 2007. link 77 Karatsoreos IN, Silver R. Minireview: The neuroendocrinology of the suprachiasmatic nucleus as a conductor of body time in mammals. Endocrinology 2007. link 78 Biffi M, Spitali G, Silvetti MS, Argnani S, Rubino I, Fontana P et al.. Atrial threshold variability: implications for automatic atrial stimulation algorithms. Pacing and clinical electrophysiology : PACE 2007. link 79 Burri H, Sunthorn H, Dorsaz PA, Viera I, Shah D. Thresholds and complications with right ventricular septal pacing compared to apical pacing. Pacing and clinical electrophysiology : PACE 2007. link 80 Sauer WH, Garcia FC, Verdino RJ, Cooper JM. Unusual pacing observed in a biventricular pacemaker with epicardial pacing leads. Pacing and clinical electrophysiology : PACE 2007. link 81 Bulava A, Lukl J. Single-centre experience with coronary sinus lead stability and long-term pacing parameters. Europace : European pacing, arrhythmias, and cardiac electrophysiology : journal of the working groups on cardiac pacing, arrhythmias, and cardiac cellular electrophysiology of the European Society of Cardiology 2007. link 82 Létienne R, Vié B, Le Grand B. Pharmacological characterisation of sodium channels in sinoatrial node pacemaking in the rat heart. European journal of pharmacology 2006. link 83 Stieber J, Wieland K, Stöckl G, Ludwig A, Hofmann F. Bradycardic and proarrhythmic properties of sinus node inhibitors. Molecular pharmacology 2006. link 84 Cantù F, De Filippo P, Cardano P, De Luca A, Gavazzi A. Validation of criteria for selective his bundle and para-hisian permanent pacing. Pacing and clinical electrophysiology : PACE 2006. link 85 Hoffmeister P, Chaudhry GM, Orlov MV, Shukla G, Haffajee CI. Sheathless implantation of permanent coronary sinus-LV pacing leads. Pacing and clinical electrophysiology : PACE 2006. link 86 Saba MM, Donahue TP, Panotopoulos PT, Ibrahim SS, Abi-Samra FM. Long-term mortality in patients with pauses in ventricular electrical activity. Pacing and clinical electrophysiology : PACE 2005. link 87 Sperzel J, Milasinovic G, Smith TW, Mead H, Brandt J, Haisty WK et al.. Automatic measurement of atrial pacing thresholds in dual-chamber pacemakers: clinical experience with atrial capture management. Heart rhythm 2005. link 88 Perzanowski C, Gilliam FR. The buddy wire technique: accessing lateral coronary veins while maintaining coronary sinus position. Journal of interventional cardiac electrophysiology : an international journal of arrhythmias and pacing 2005. link 89 Knutsson A. Methodological aspects of shift-work research. Chronobiology international 2004. link 90 Rosen MR, Robinson RB, Brink P, Cohen IS. Recreating the biological pacemaker. The anatomical record. Part A, Discoveries in molecular, cellular, and evolutionary biology 2004. link 91 Noiseux N, Khairy P, Fournier A, Vobecky SJ. Thirty years of experience with epicardial pacing in children. Cardiology in the young 2004. link 92 Hexamer M, Meine M, Kloppe C, Kloppe A, Mügge A, Werner J. The dromotropic pacemaker: system analysis and design considerations. Biomedizinische Technik. Biomedical engineering 2004. link 93 Morin LP, Blanchard JH, Provencio I. Retinal ganglion cell projections to the hamster suprachiasmatic nucleus, intergeniculate leaflet, and visual midbrain: bifurcation and melanopsin immunoreactivity. The Journal of comparative neurology 2003. link 94 Kürüm T, Yüksel M, Ozbay G, Söyük S, Türe M. Relationship with plasma neurohormones and dyssynchrony detected by Doppler echocardiography in patients undergoing permanent pacemaker implantation. Acta cardiologica 2003. link 95 Trigano JA, Caucino K, Sbragia P, Paganelli F, Levy S. Right atrial sensing for VDD pacing through a persistent left superior vena cava. Clinical cardiology 2003. link 96 Badiu C. Genetic clock of biologic rhythms. Journal of cellular and molecular medicine 2003. link 97 Barold SS. Far-field R wave sensing causing prolongation of the atrial escape interval of DDD pacemakers with atrial-based lower rate timing. Pacing and clinical electrophysiology : PACE 2003. link 98 Fabiani A, Burali A, Manfredini E, Corbucci G, Bolognese L. VDD pacemaker replacement independently of the implanted lead: a prospective study. Italian heart journal : official journal of the Italian Federation of Cardiology 2003. link 99 Sornborger A, Sirovich L, Morley G. Extraction of periodic multivariate signals: mapping of voltage-dependent dye fluorescence in the mouse heart. IEEE transactions on medical imaging 2003. link 100 Malm D, Svensson E, Karlsson JE, Fridlund B. Health-related quality of life in pacemaker patients: a single and multidimensional self-rated health comparison study. European journal of cardiovascular nursing 2003. link00065-3)

    Original source

    1. [1]
      A Novel Risk Score for Predicting the Difficulty in Leadless Pacemaker Implantation.Ishizue N, Fukaya H, Oikawa J, Shinkai W, Suyama T, Toraiwa M et al. Journal of cardiovascular electrophysiology (2026)
    2. [2]
      Sudden Micra VR Battery Failure With Telemetry Loss and Fluoroscopic Battery Deformation.Nakamura Y, Aiyama Y, Miki K, Kunimoto E, Ishikawa T, Arai S et al. Pacing and clinical electrophysiology : PACE (2026)
    3. [3]
      Novel Pacing Mode Conserves Battery in Dual-Chamber Leadless Pacemakers.Ip JE, Badie N, Rashtian M, Nair DG, Banker R, Hadadi C et al. Journal of cardiovascular electrophysiology (2026)
    4. [4]
      Behavior of leadless atrioventricular synchronous pacing during exercise.Garweg C, Van Weyenbergh T, Sheldon T, Anders CC, Dorrestijn A, Poels P et al. Heart rhythm (2025)
    5. [5]
      Novel approach to left bundle branch area pacing lead implantation using a 3-dimensional stylet.Ludwik B, Labus M, Roleder T, Moskal P, Kiełbasa G, Śpikowski J et al. Heart rhythm (2025)
    6. [6]
      Left atrial strain is a good predictor of atrio-ventricular synchrony in leadless pacemaker pacing.Troisi F, Caccavo VP, Santobuono VE, Sgarra L, Carella MC, Basile P et al. Journal of cardiovascular electrophysiology (2024)
    7. [7]
      Optimizing conduction system pacing lead placement utilizing the image overlay technique.Pharithi RB, Ayeni M, Makharia M, Keene D, Khiani R Pacing and clinical electrophysiology : PACE (2024)
    8. [8]
      Evaluation of a smartphone electrocardiograph in healthy foals and comparison to standard base-apex electrocardiography.Bindi F, Vezzosi T, Sala G, Freccero F, Marmorini P, Bonelli F et al. Veterinary research communications (2024)
    9. [9]
      Editorial for the Tribulova N International journal of molecular sciences (2023)
    10. [10]
    11. [11]
      Biventricular Function is Impaired in Right Ventricular Septal Pacing-A Prospective Study Using Myocardial Strain Imaging.Toner L, Chen JXC, Ramchand J, Srivastava P, O'Donnell D, Calafiore P et al. Heart, lung & circulation (2023)
    12. [12]
      Premature beat of selective left bundle branch: a novel marker for reaching and capturing the left bundle branch.Shen J, Jiang L, Jiang F, Wu H, Cai X, Zhuo S et al. Journal of interventional cardiac electrophysiology : an international journal of arrhythmias and pacing (2023)
    13. [13]
      Differentiating left bundle branch pacing and left ventricular septal pacing: An algorithm based on intracardiac electrophysiology.Chen X, Qian Z, Zou F, Wang Y, Zhang X, Qiu Y et al. Journal of cardiovascular electrophysiology (2022)
    14. [14]
      Leadless pacemaker implantation: An unexpected complication.Berdaoui B, Pintea Bentea G, Samyn S, Morissens M, Castro Rodriguez J Pacing and clinical electrophysiology : PACE (2022)
    15. [15]
      Pacemaker lead related myocardial perforation.Kumar P, Skrabal J, Frasure SE, Pourmand A The American journal of emergency medicine (2022)
    16. [16]
      Leadless pacemaker implantation under direct visualization during valve surgery.Shivamurthy P, Miller MA, El-Eshmawi A, Boateng P, Pandis D, Pawale A et al. The Journal of thoracic and cardiovascular surgery (2022)
    17. [17]
      Permanent pacemaker implantation associated tricuspid regurgitation.Niazi GZK, Masood A, Ahmed N, Qadir I, Akhtar A, Saleemi MS et al. Asian cardiovascular & thoracic annals (2021)
    18. [18]
      A circadian clock in the sinus node mediates day-night rhythms in Hcn4 and heart rate.D'Souza A, Wang Y, Anderson C, Bucchi A, Baruscotti M, Olieslagers S et al. Heart rhythm (2021)
    19. [19]
      Transthoracic echocardiography-guided left bundle branch pacing without fluoroscopic guidance: A case report.Tan K, Deng X, Wang S, Liu C, Zhao R, Xiong F Journal of clinical ultrasound : JCU (2021)
    20. [20]
      The merits of the ICD for inherited heart rhythm disorders: A critical re-appraisal.Roston TM, Krahn AD, Ong K, Sanatani S Trends in cardiovascular medicine (2020)
    21. [21]
      Effects of circadian rhythm disorder on the hippocampus of SHR and WKY rats.Wang Y, Zhang Y, Wang W, Liu X, Chi Y, Lei J et al. Neurobiology of learning and memory (2020)
    22. [22]
      Programmed deep septal stimulation: A novel maneuver for the diagnosis of left bundle branch capture during permanent pacing.Jastrzębski M, Moskal P, Bednarek A, Kiełbasa G, Kusiak A, Sondej T et al. Journal of cardiovascular electrophysiology (2020)
    23. [23]
    24. [24]
      Small-conductance calcium-activated potassium current modulates the ventricular escape rhythm in normal rabbit hearts.Wan J, Chen M, Wang Z, Everett TH, Rubart-von der Lohe M, Shen C et al. Heart rhythm (2019)
    25. [25]
      Identification and management of a subacute right ventricular perforation by an active-fixation permanent pacemaker lead in a dog.García-Guasch L, Sá Borges C, Sousa P, Manubens Grau J Journal of veterinary cardiology : the official journal of the European Society of Veterinary Cardiology (2019)
    26. [26]
      An indissoluble knot: An unexpected troubleshooting during Micra implantation.Cipolletta L, Volpato G, Biffi M, Capucci A Pacing and clinical electrophysiology : PACE (2019)
    27. [27]
      Management of a leadless pacemaker recall via extraction in a patient with a history of multiple previous device implants.Curnis A, Cerini M, Inama L, Vassanelli F, Mariggiò D, Salghetti F et al. Journal of electrocardiology (2019)
    28. [28]
      Extraction of a dislocated leadless pacemaker in a patient with infective endocarditis and repeated endocardial and epicardial pacing system infections.Taborsky M, Skala T, Kocher M, Fedorco M Biomedical papers of the Medical Faculty of the University Palacky, Olomouc, Czechoslovakia (2019)
    29. [29]
      Prospective Study of Tricuspid Regurgitation Associated With Permanent Leads After Cardiac Rhythm Device Implantation.Van De Heyning CM, Elbarasi E, Masiero S, Brambatti M, Ghazal S, Al-Maashani S et al. The Canadian journal of cardiology (2019)
    30. [30]
      Upper rate behavior in six dogs with dual-chamber pacemakers.Potter BM, Ames MK, Toffoli AM, Scansen BA Journal of veterinary cardiology : the official journal of the European Society of Veterinary Cardiology (2019)
    31. [31]
      Electrical parameters for physiological His-Purkinje pacing vary by implant location in an ex vivo canine model.Mattson AR, Mattson E, Mesich ML, Yang Z, Iaizzo PA Heart rhythm (2019)
    32. [32]
      Pacemaker reprogramming rarely needed after device replacement.Curila K, Smida J, Herman D, Osmancik P, Stros P, Zdarska J et al. Herz (2019)
    33. [33]
      Intraoperative Implantation of Micra Leadless Pacemaker During Valve Surgery.Marai I, Diab S, Ben-Avi R, Kachel E The Annals of thoracic surgery (2018)
    34. [34]
      Sensitivity of the circadian system to evening bright light in preschool-age children.Akacem LD, Wright KP, LeBourgeois MK Physiological reports (2018)
    35. [35]
      Mortality and Cerebrovascular Events After Heart Rhythm Disorder Management Procedures.Lee JZ, Ling J, Diehl NN, Hodge DO, Padmanabhan D, Killu AM et al. Circulation (2018)
    36. [36]
    37. [37]
      A Novel Mechanism for Human Cardiac Ankyrin-B Syndrome due to Reciprocal Chromosomal Translocation.Huq AJ, Pertile MD, Davis AM, Landon H, James PA, Kline CF et al. Heart, lung & circulation (2017)
    38. [38]
      Effectiveness of pacemaker tele-monitoring on quality of life, functional capacity, event detection and workload: The PONIENTE trial.Lopez-Villegas A, Catalan-Matamoros D, Robles-Musso E, Peiro S Geriatrics & gerontology international (2016)
    39. [39]
      Inadequacy of fluoroscopy and electrocardiogram in predicting septal position in RVOT pacing - Validation with cardiac computed tomography.Sharma G, Salahuddin S, Sanders P, Gupta H, Gulati G, Jagia P et al. Indian heart journal (2016)
    40. [40]
      Right Bundle Branch Block-Like Pattern During Uncomplicated Right Ventricular Pacing and the Effect of Pacing Site.Tzeis S, Andrikopoulos G, Weigand S, Grebmer C, Semmler V, Brkic A et al. The American journal of cardiology (2016)
    41. [41]
      A Leadless Intracardiac Transcatheter Pacing System.Reynolds D, Duray GZ, Omar R, Soejima K, Neuzil P, Zhang S et al. The New England journal of medicine (2016)
    42. [42]
      Incidence, predictors, and outcome of inadvertent malposition of transvenous pacing or defibrillation lead in the left heart.Ohlow MA, Roos M, Lauer B, Von Korn H, Geller JC Europace : European pacing, arrhythmias, and cardiac electrophysiology : journal of the working groups on cardiac pacing, arrhythmias, and cardiac cellular electrophysiology of the European Society of Cardiology (2016)
    43. [43]
      Optimal management of Riata leads with no known electrical abnormalities or externalization: a decision analysis.Pokorney SD, Zhou K, Matchar DB, Love S, Zeitler EP, Lewis R et al. Journal of cardiovascular electrophysiology (2015)
    44. [44]
      The analysis of indications and early results of transvenous lead extraction in patients with a pacemaker, ICD and CRT - single-center experience.Zabek A, Malecka B, Haberka K, Boczar K, Pfitzner R, Debski M et al. Acta cardiologica (2015)
    45. [45]
      Apparent acute reversible right ventricular pacing-induced left ventricular dysfunction.Te CC, Stavrakis S, Lozano P, Reynolds D Journal of cardiovascular electrophysiology (2013)
    46. [46]
      The relationship between right ventricular lead position and paced QRS duration.Kawakami T, Tanaka N, Ohno H, Kobayakawa H, Sakurai T, Ishihara H et al. Pacing and clinical electrophysiology : PACE (2013)
    47. [47]
      Incidence and predictors of pericardial effusion after permanent heart rhythm device implantation: prospective evaluation of 968 consecutive patients.Ohlow MA, Lauer B, Brunelli M, Geller JC Circulation journal : official journal of the Japanese Circulation Society (2013)
    48. [48]
      Right-sided implantation of a cardiac resynchronization therapy defibrillator in a case of persistent left superior vena cava.Korantzopoulos P, Grekas G, Goudevenos JA Hellenic journal of cardiology : HJC = Hellenike kardiologike epitheorese (2013)
    49. [49]
      Biological clocks: who in this place set up a sundial?Foster RG Current biology : CB (2012)
    50. [50]
      Prolapsed double-canted bipolar left ventricular lead for pacing the left atrium via the coronary sinus: experience in 11 patients.Worley SJ, Gohn DC Europace : European pacing, arrhythmias, and cardiac electrophysiology : journal of the working groups on cardiac pacing, arrhythmias, and cardiac cellular electrophysiology of the European Society of Cardiology (2012)
    51. [51]
      Are elderly patients at increased risk of complications following pacemaker implantation? A meta-analysis of randomized trials.Armaganijan LV, Toff WD, Nielsen JC, Andersen HR, Connolly SJ, Ellenbogen KA et al. Pacing and clinical electrophysiology : PACE (2012)
    52. [52]
      A randomized trial of long-term remote monitoring of pacemaker recipients (the COMPAS trial).Mabo P, Victor F, Bazin P, Ahres S, Babuty D, Da Costa A et al. European heart journal (2012)
    53. [53]
      ICD lead implantation following sharp cannulation of a blocked superior vena cava.Sadarmin PP, Uberoi R, Tomlinson DR, Betts TR Pacing and clinical electrophysiology : PACE (2011)
    54. [54]
      External monitoring-induced pacemaker-driven tachycardia: a case report.Trocinski DR, Pickens AT The Journal of emergency medicine (2011)
    55. [55]
      Utility of the surface electrocardiogram for confirming right ventricular septal pacing: validation using electroanatomical mapping.Burri H, Park CI, Zimmermann M, Gentil-Baron P, Stettler C, Sunthorn H et al. Europace : European pacing, arrhythmias, and cardiac electrophysiology : journal of the working groups on cardiac pacing, arrhythmias, and cardiac cellular electrophysiology of the European Society of Cardiology (2011)
    56. [56]
      Safety and performance of a system specifically designed for selective site pacing.Zanon F, Svetlich C, Occhetta E, Catanzariti D, Cantù F, Padeletti L et al. Pacing and clinical electrophysiology : PACE (2011)
    57. [57]
      Muscle noise effects on atrial evoked response sensing: implications on atrial auto-threshold and auto-capture determination.Tse HF, Saha S, Garg A, Bohn D, Lee YL, Lau CP Pacing and clinical electrophysiology : PACE (2011)
    58. [58]
      A tale of four atrioventricular intervals.Subramanian A, Selvaraj RJ, Cameron D Europace : European pacing, arrhythmias, and cardiac electrophysiology : journal of the working groups on cardiac pacing, arrhythmias, and cardiac cellular electrophysiology of the European Society of Cardiology (2010)
    59. [59]
    60. [60]
      Left-sided biventricular pacemaker implantation in the presence of persistent left superior vena cava.Sankhla V, Vajifdar B, Shah M, Lokhandwala Y Indian heart journal (2010)
    61. [61]
      Actual pacemaker longevity: the benefit of stimulation by automatic capture verification.Biffi M, Bertini M, Saporito D, Ziacchi M, Martignani C, Diemberger I et al. Pacing and clinical electrophysiology : PACE (2010)
    62. [62]
      Functional role of CLC-2 chloride inward rectifier channels in cardiac sinoatrial nodal pacemaker cells.Huang ZM, Prasad C, Britton FC, Ye LL, Hatton WJ, Duan D Journal of molecular and cellular cardiology (2009)
    63. [63]
    64. [64]
      Long-term results of high vs. normal impedance ventricular leads on actual (Real-Life) pacemaker generator longevity.Etsadashvili K, Hintringer F, Stühlinger M, Dichtl W, Spuller K, Antretter H et al. Europace : European pacing, arrhythmias, and cardiac electrophysiology : journal of the working groups on cardiac pacing, arrhythmias, and cardiac cellular electrophysiology of the European Society of Cardiology (2009)
    65. [65]
      Paradoxical increase of stimulus to atrium interval despite His-bundle capture during para-Hisian pacing.van Opstal JM, Crijns HJ Europace : European pacing, arrhythmias, and cardiac electrophysiology : journal of the working groups on cardiac pacing, arrhythmias, and cardiac cellular electrophysiology of the European Society of Cardiology (2009)
    66. [66]
      Right ventricular apical pacing: the unwanted model of cardiac stimulation?Pachón Mateos JC, Pachón Mateos EI, Pachón Mateos JC Expert review of cardiovascular therapy (2009)
    67. [67]
      Clinical benefits of remote versus transtelephonic monitoring of implanted pacemakers.Crossley GH, Chen J, Choucair W, Cohen TJ, Gohn DC, Johnson WB et al. Journal of the American College of Cardiology (2009)
    68. [68]
      Pacing and defibrillation lead exchange without vein puncture.Antonelli D, Freedberg NA, Turgeman Y Pacing and clinical electrophysiology : PACE (2009)
    69. [69]
      Routine follow-up after pacemaker implantation: frequency, pacemaker programming and professionals in charge.van Eck JW, van Hemel NM, de Voogt WG, Meeder JG, Spierenburg HA, Crommentuyn H et al. Europace : European pacing, arrhythmias, and cardiac electrophysiology : journal of the working groups on cardiac pacing, arrhythmias, and cardiac cellular electrophysiology of the European Society of Cardiology (2008)
    70. [70]
      Implantation of lumenless pacing leads at the inter-atrial septum and right ventricular outflow tract with deflectable catheter-sheath.Bai R, Kam R, Ching CK, Hsu LF, Teo WS Journal of Huazhong University of Science and Technology. Medical sciences = Hua zhong ke ji da xue xue bao. Yi xue Ying De wen ban = Huazhong keji daxue xuebao. Yixue Yingdewen ban (2008)
    71. [71]
    72. [72]
      Performance of a ventricular automatic-capture algorithm in a wide clinical setting.Pecora D, Morandi F, Liccardo M, Pepi P, Orazi S, Caico SI et al. Pacing and clinical electrophysiology : PACE (2008)
    73. [73]
      Intermittent atrial sensing in a VDD pacemaker.Carbone V, Carerj S, Oreto G Journal of electrocardiology (2008)
    74. [74]
      A novel approach in R peak detection using Hybrid Complex Wavelet (HCW).Fard PJ, Moradi MH, Tajvidi MR International journal of cardiology (2008)
    75. [75]
      Rescue permanent iliac vein pacing after epicardial lead failure: an unusual reversal of pacing fortune.Gupta A, Halleran SM, Krishnan K, Trohman RG Europace : European pacing, arrhythmias, and cardiac electrophysiology : journal of the working groups on cardiac pacing, arrhythmias, and cardiac cellular electrophysiology of the European Society of Cardiology (2008)
    76. [76]
      Low amplitude P, QRS and T wave pattern in lead I--the "isoelectric lead I sign".MacKenzie R Journal of insurance medicine (New York, N.Y.) (2007)
    77. [77]
    78. [78]
      Atrial threshold variability: implications for automatic atrial stimulation algorithms.Biffi M, Spitali G, Silvetti MS, Argnani S, Rubino I, Fontana P et al. Pacing and clinical electrophysiology : PACE (2007)
    79. [79]
      Thresholds and complications with right ventricular septal pacing compared to apical pacing.Burri H, Sunthorn H, Dorsaz PA, Viera I, Shah D Pacing and clinical electrophysiology : PACE (2007)
    80. [80]
      Unusual pacing observed in a biventricular pacemaker with epicardial pacing leads.Sauer WH, Garcia FC, Verdino RJ, Cooper JM Pacing and clinical electrophysiology : PACE (2007)
    81. [81]
      Single-centre experience with coronary sinus lead stability and long-term pacing parameters.Bulava A, Lukl J Europace : European pacing, arrhythmias, and cardiac electrophysiology : journal of the working groups on cardiac pacing, arrhythmias, and cardiac cellular electrophysiology of the European Society of Cardiology (2007)
    82. [82]
      Pharmacological characterisation of sodium channels in sinoatrial node pacemaking in the rat heart.Létienne R, Vié B, Le Grand B European journal of pharmacology (2006)
    83. [83]
      Bradycardic and proarrhythmic properties of sinus node inhibitors.Stieber J, Wieland K, Stöckl G, Ludwig A, Hofmann F Molecular pharmacology (2006)
    84. [84]
      Validation of criteria for selective his bundle and para-hisian permanent pacing.Cantù F, De Filippo P, Cardano P, De Luca A, Gavazzi A Pacing and clinical electrophysiology : PACE (2006)
    85. [85]
      Sheathless implantation of permanent coronary sinus-LV pacing leads.Hoffmeister P, Chaudhry GM, Orlov MV, Shukla G, Haffajee CI Pacing and clinical electrophysiology : PACE (2006)
    86. [86]
      Long-term mortality in patients with pauses in ventricular electrical activity.Saba MM, Donahue TP, Panotopoulos PT, Ibrahim SS, Abi-Samra FM Pacing and clinical electrophysiology : PACE (2005)
    87. [87]
      Automatic measurement of atrial pacing thresholds in dual-chamber pacemakers: clinical experience with atrial capture management.Sperzel J, Milasinovic G, Smith TW, Mead H, Brandt J, Haisty WK et al. Heart rhythm (2005)
    88. [88]
      The buddy wire technique: accessing lateral coronary veins while maintaining coronary sinus position.Perzanowski C, Gilliam FR Journal of interventional cardiac electrophysiology : an international journal of arrhythmias and pacing (2005)
    89. [89]
      Methodological aspects of shift-work research.Knutsson A Chronobiology international (2004)
    90. [90]
      Recreating the biological pacemaker.Rosen MR, Robinson RB, Brink P, Cohen IS The anatomical record. Part A, Discoveries in molecular, cellular, and evolutionary biology (2004)
    91. [91]
      Thirty years of experience with epicardial pacing in children.Noiseux N, Khairy P, Fournier A, Vobecky SJ Cardiology in the young (2004)
    92. [92]
      The dromotropic pacemaker: system analysis and design considerations.Hexamer M, Meine M, Kloppe C, Kloppe A, Mügge A, Werner J Biomedizinische Technik. Biomedical engineering (2004)
    93. [93]
    94. [94]
    95. [95]
      Right atrial sensing for VDD pacing through a persistent left superior vena cava.Trigano JA, Caucino K, Sbragia P, Paganelli F, Levy S Clinical cardiology (2003)
    96. [96]
      Genetic clock of biologic rhythms.Badiu C Journal of cellular and molecular medicine (2003)
    97. [97]
    98. [98]
      VDD pacemaker replacement independently of the implanted lead: a prospective study.Fabiani A, Burali A, Manfredini E, Corbucci G, Bolognese L Italian heart journal : official journal of the Italian Federation of Cardiology (2003)
    99. [99]
      Extraction of periodic multivariate signals: mapping of voltage-dependent dye fluorescence in the mouse heart.Sornborger A, Sirovich L, Morley G IEEE transactions on medical imaging (2003)
    100. [100]
      Health-related quality of life in pacemaker patients: a single and multidimensional self-rated health comparison study.Malm D, Svensson E, Karlsson JE, Fridlund B European journal of cardiovascular nursing (2003)

    HemoChat

    by SPINAI

    Evidence-based clinical decision support powered by SNOMED-CT, Neo4j GraphRAG, and NASS/AO/NICE guidelines.

    ⚕ For clinical reference only. Not a substitute for professional judgment.

    © 2026 HemoChat. All rights reserved.
    Research·Pricing·Privacy & Terms·Refund·SNOMED-CT · NASS · AO Spine · NICE · GraphRAG